Safety considerations between artificial rock farms and building structures


In the previous chapter, we mentioned that a professional manufacturer of artificial rock yards should have the ability to provide design drawings and also provide information on safety mechanics analysis of rock structures to architects. Because of the construction of artificial rock sites, safety is always the first consideration. An artificial rock field is no better designed, but if there is a problem with structural safety, it will completely lose their effectiveness. Just as there are certain artificial rock formations that have just been built for safety reasons, they stand quietly on a certain land and go on a realm that no one dares to use. No matter who the money is from this rock farm, It is a waste of human resources, and this is only due to the lack of professionalism in the original design, resulting in such consequences.

Therefore, the design of artificial rock farms is the first priority. Architects stand in the position of protecting the public and need to clarify the responsibility of each other with the manufacturers of artificial rock farms. In simple terms, an architect can use his professional knowledge to take responsibility for the safety of the building itself. However, an artificial rock farm manufacturer must take responsibility for the safety assurance of the rock farms he provides and the building parts to which the rock farms are attached.

According to the regulations of European artificial rock yard safety standards, manufacturers of artificial rock farms must also provide the safety mechanics analysis data of the rock field structure to the owner to prove that the structure of the artificial rock farm fully complies with the provisions of the safety standard. Companies that are unable to provide this service will be deemed to be inconsistent with this artificial rock site safety standard.

â—Ž The structural safety analysis data can be divided into two parts to illustrate:
The first is the structural safety of the artificial rock site itself. In addition to the static weight load of the rock slab itself and its components, the structural body of the artificial rock field must also consider the impact of the user on the dynamic load generated by the fall during the climbing process. All these have international standards for reference. We will elaborate on the safety standards of artificial rock yards developed by the European Union in the next chapter. In addition to these, if the rock site is built outdoors, it is necessary to consider the effects of weather and strong winds. For example, due to the typhoon in Taiwan, the structural design of the outdoor rock site must be able to withstand strong winds of 150km/hr. Not damaged.

After calculation, we can list the material, shape, size, and quantity of the structural materials needed to meet the safety standards as a basis for the design, and these must be submitted with relevant data for the architect or its structural engineer. Can audit.
Second, if the structure of the rock site itself is well-designed, if the rock site is to be attached to a building, the stress analysis of the joint between the rock site structure and the building must be calculated so that the architect can check him accordingly. Whether the originally designed building structure can withstand the load imposed by this artificial rock yard. If it is found to have exceeded, the architect may need to change its own structural design depending on the situation, or require the artificial rock farm manufacturer to change the design of the rock farm in accordance with the architect's new data. All in all, both parties must go through this process, sign and confirm each other, accept each other's data and design, in order to clarify the future attribution of responsibility. Once the parties confirm, the artificial rock farm manufacturer will build or design the rock ontology, The part to which it is attached is completely responsible.

From the above description, we can understand how important the structural safety mechanics analysis is proposed by the artificial rock farm manufacturer. Without this step, light can only be hidden by sending a bunch of beautiful design drawings. There are some potential structural hazards that can absolutely be avoided by providing advance analysis of the mechanical structure of the artificial rock structure and then confirming by both parties.

â–¡Note â–¡
In order to prevent some contractors from rushing to bid at low prices, and then constructing the rock site with materials and construction methods that are not in compliance with safety standards, the architect or owner can indicate on the ticket that the successful contractor must provide the site before construction. Structural safety mechanics analysis data may only be accepted by the architect or owner before entering the site. If the contractor's professionalism is insufficient, this information will not be able to be submitted. This can filter these bad contractors.

340 Home Used Treadmill

340 Home Used Treadmill,Home Ultra-Thin Treadmill,Mini Walker Home Treadmill,New Motorized Home Treadmill

Ningbo Kangruida Sports Equipment Co.,Ltd , http://www.kreedatreadmill.com