JOYN brand aseptic homogenizer instruction manual


The Qiaoyue brand aseptic homogenizer developed by Shanghai Qiaoyue Electronics Co., Ltd. makes the process of extracting bacteria from solid samples very simple, just add the sample and diluent to the sterile sample bag, and then The sample bag is placed in the beater homogenizer to complete the sample processing. Effectively separate the homogeneous sample of microorganisms contained within and on the solid sample to ensure that all samples are mixed in the sterile bag. The treated sample solution can be directly sampled and analyzed without the risk of sample changes and cross-contamination.
First, the function of aseptic homogenizer: Sterile homogenizer is widely used in animal tissue, biological samples, drug analysis, food, cosmetics homogenization treatment, especially suitable for the preparation of microbiological test samples, samples without pollution, no damage It does not heat up, does not require sterilization, and does not require the characteristics of washing utensils. It is also suitable for tumors in the medical field.
Second, the main features of the aseptic homogenizer:
● Large screen LCD display.
● Three sets of work programs can be stored.
● Adjustable homogenization time.
● The homogenization speed can be adjusted or fixed.
●Picker can adjust the distance between front and rear.
● Sterile disposable filter bags to ensure hygiene and safety.
● Fully open door, easy to clean.
● Glass transparent window is easy to observe.
●The sample is not in contact with the homogenizer. If there is no sample leakage, no system cleaning is required.
●The homogenization is soft, the sample is non-polluting, no damage, no heating, no need for sterilization, no need to wash the utensils.
Third, the use of aseptic homogenizer:
1. Put the sample to be processed into a sterile homogenized bag.
2. Open the homogenizer door (can be fully opened) and clamp the sterile bag opening when closing the homogenizer door.
3. Set the usage program (such as the slap speed, slap time, etc.) to perform the slap homogenization work.
4. After the experiment is completed, open the homogenizer door and take out the sample.
Fourth, the use of aseptic homogenizer notes:
1) The power plug must be tightly inserted. Looseness may affect the computer controller to cause a crash. If there is a crash, please turn off the rear power switch and restart after 3 minutes of shutdown.
2) Do not open the homogenizer door when working on the hammer plate to avoid overflow of the sample liquid. It should be built according to “on/off” and the equipment will stop running automatically. When the door is closed, press “Open/Stop” to build, and the equipment will automatically complete the remaining work. Do not reverse the operation.
3) If the instrument is not used for a long time, the power should be cut off and the plug should be removed. Prevent the aging of electronic components inside the aseptic homogenizer.
4) The bottom of the homogenizer door prevents the accidental rupture of the homogeneous bag, which is convenient for cleaning the spill. The bottom design is empty, and the water tray can be placed. Therefore, do not extend the hand from the bottom when the instrument is running, so as to avoid scratching the finger. When the homogenizer is working, it is best not to open the homogenizer door, causing unnecessary losses.
5) Before the machine is running, please check the homogenization box for foreign matter to avoid malfunction and damage to the homogenized bag during work.
6) Hard and sharp materials such as hard blocks, bones, and ice should not be used to avoid damage to the homogeneous bag.
7) The instrument and the homogenized bag should be stored in direct sunlight. In particular, the homogenized bag should be stored in a place free of sunlight or ultraviolet rays to avoid aging.
8) When the amount is small, when the speed is higher, when the homogenized fiber is tougher, the rear knob can be used to adjust the spacing between the slap plate and the window to achieve better homogenization. Pay attention to the adjusted distance to avoid the occurrence of damage to the aseptic homogenizer caused by air strikes.

Single-hole bar stock for drilling and milling cutters